Contact Advantech Search Shopping list
  1. 1-888-576-9668
  2. Login
Order By Part Number

AMAX-3285IO-AE 8-axis EtherCAT Motion Slave Module with 16DI/16DO

  1. Max. 5 MHz, 8-axis pulse output
  2. Encoder input is 10 MHz for 4xAB mode, 2.5 MHz for CW/CCW mode
  3. BoardID is switchable
  4. Easily visible LED indicators on board to do diagnosis
  5. Direct wire to servo drive to save terminal board space while installation
  6. Horizontal installation for for servo or stepping motor driver
  7. Suitable for DIN-rail mounting
  8. Programmable interrupt
  9. Memory buffer (10K points) for trajectory planning which is designed in DSP
Please visit via PC to place order/quote

$600.00

Make an inquiry Add to Quote Add to Cart
Specifications
Category
Attribute
Value
General
Bus Type
EtherCAT
General
Certification
CE, FCC Class A
General
Connectors
2 x RJ-45 for communication port / 1 x Terminal block (4P) for power / 1 x Terminal block (2P) for +5V output / 8 x DB-26 connector by transfer cable to servo drives / 8 x Terminal block (16P) for home, Limit, LTC, CMP and extra 16DI/16DO
General
Dimensions (L x W x H)
255 x 141 x 60 mm (5.6 x 4.3 x 2.4")
General
Humidity
5 ~ 95% RH, non-condensing (IEC 60068-2-3)
General
Operating Temperature
0 ~ 60°C (32 ~ 140°F)
General
Power Consumption
15W MAX (625mA @ 24V)
General
Power Input
24VDC ±10%
Encoder Interface
Counts per Enc. Cycle
x1, x2, x4 (A/B phase only)
Encoder Interface
Input Range
Low: 0 ~ 0.5V / High: 3.5 ~ 7V
Encoder Interface
Input Type
A/B phase, CW/CCW
Encoder Interface
Isolation Protection
2,500 VRMS
Encoder Interface
Max. Input Frequency
10 MHz @ 4xAB
Pulse Type Motion Control
Home Modes
16 home mode + home motion defined by CiA402
Pulse Type Motion Control
Local I/O - General Input Signal
Input voltage: 24Vdc Max. / Input delay: 100us Max. (isolation delay) / Signal: EMG (emergency stop); ORG, LMT+, LMT-; INPOS (in position signal); LTC (counter latch); RDY (servo ready); ALARM (servo alarm)
Pulse Type Motion Control
Local I/O - General Output Signal
Output voltage: Open collect 24Vdc Max / Output delay: 100us Max. (isolation delay) / Sink current: 100mA per channel / Signal: CMP (position compare in range output); SVON (servo on); RALM (reset driver alarm); ERC (counter clear signal)
Pulse Type Motion Control
Local I/O - General Purpose I/O
16DI/16DO (terminal block)
Pulse Type Motion Control
Max. Output Speed
5 Mbps
Pulse Type Motion Control
Motor Driver Support
Pulse-type servo
Pulse Type Motion Control
Number of Axes
8
Pulse Type Motion Control
Pulse Output Type
OUT/DIR, CW/CCW
Pulse Type Motion Control
Step Count Range
±134, 217, 728
Pulse Type Motion Control
Velocity Profiles
T-Curve, S-Curve
x
Contact Us

1-888-576-9668

8 am- 8 pm (EST) Mon-Fri

Contact Advantech